ATP1000 Touchpad/Display Installation Instructions Product summary The ATP1000 lets you control all programming and operation of compatible security systems (see the “Specifications” section). The large 2-line, 16-character display provides easy to read. User’s Manual.
Connecting the touchpad for system
programming only
For installations that don’t include an alphanumeric touchpad
as a permanent part of the system, you can connect one for
system programming to the Programming Touchpad Header
on the panel.
To do this you must first connect a Programming Touchpad
Cable (60-791) to the touchpad wires (see Programming
Touchpad Cable Installation Instructions—466-1604, included
with the cable). Then, use the appropriate procedure for
connecting the touchpad.
To connect a programming touchpad to a Concord
Express, Concord, or Concord Ultra panel with software
version 2.0 or later:
1. With the panel powered up, connect the cable to the
Programming Touchpad Header (see
).
Caution:
When using the ATP1000 as a programmable
touchpad, be careful not to touch the circuit board exposed on
the pack.
Figure 4. Connecting a Programming Touchpad—Concord
Express Shown, Concord Similar
Programming Touchpad Header Pins
2. Activate the touchpad by pressing 8 + CODE + 0 + 2.
3. Enter program mode by pressing 8 + installer/dealer
CODE + 0 + 0 and program the panel using the panel
Installation Instructions.
4. When programming is completed, simply disconnect the
programming touchpad.
To connect a programming touchpad to a Concord panel
with software versions 1.0–1.6:
1. Disconnect AC and backup battery power.
2. Connect the cable plug onto the panel Programming
Touchpad Header pins (see
).
3. Reconnect the AC and backup battery power. The
touchpad briefly displays ***********, SCANNING BUS
DEVICES, then shows a time and date display.
Note: If the touchpad does not respond as described in
step 3, there may be a bus conflict. To correct this, change
the touchpad unit number as described in the section
“Changing the Touchpad Unit Number.”
Removing the programming touchpad from Concord
Ge Security Interlogix 60-983 Atp1000 Manual
panels with software versions 1.0–1.6:
To prevent a trouble condition, you must delete the
programming touchpad unit number from Concord panel
memory before disconnecting it.
1. After programming is completed, return to the
ACCESSORY MODULES menu, then press É. The
display should read BUS DEVICES.
2. Press É. The display shows the lowest unit number and its
device name.
3. Press A or B until the display shows the programming
touchpad unit number.
Ge Security 60-983 Atp1000 Alphanumeric Touchpad Manual
4. Press D to delete the device and its unit number from
Ge Security 60-983 Atp1000 Alphanumeric Touchpad User Manual
panel memory. The display shows:
UNIT - TYPE
14-NONE
5. Exit program mode and disconnect the programming cable
from the panel header.
Testing
Note: Contact the central monitoring station before
Ge Security 60-983 Atp1000 Manual
activating alarms, to avoid dispatching local police and fire
departments.
Test the touchpad by arming/disarming the system, activating
the touchpad panics, bypassing sensors, and by turning chime
and lights on/off to verify correct operation. Refer to the panel
User’s Manual for complete system operating instructions.
Adjusting display brightness and contrast
The touchpad display can be adjusted for easier viewing to
help compensate for lighting conditions in the touchpad
location.
The brightness adjustment lightens or darkens the background.
Ge Security 60-983 Atp1000 User Manual
The contrast adjustment lightens or darkens the text.
ATP1000 Touchpad/Display Installation Instructions