Dometic air conditioners replace your RV roof vent with an aerodynamic cooling unit, and the entire installation process is easily completed with basic tools. The roof vent already exists, so you'll simply swap the vent for your air conditioning unit. Having air conditioning in your RV creates a much more pleasant situation in hot weather. Has anyone have any idea what could cause this issue? It is a Dometic rear AC with HP and will not cool at all. The fan runs but no cooling at all. I hate to have to pack up to go to a dealer since we are full-timing. And I really don't know of a good Dealer in the area. If I cant fix then I.

Advertising

13

! ! WARNING

DO NOT USE A FLAME

TO CHECK FOR GAS LEAKS.

C. Check the control system by connecting/disconnecting

120 volt AC power, start/stop the engine, etc. Compare
the operation with the operation described in

Section C.

Operation Instructions.

D. The LP gas pressure should be checked and the main

regulator readjusted if pressure is incorrect. The correct
operating pressure is 11 inches of water column. The
correct place to take the LP gas pressure is at the test
port just ahead of the burner jet. (See FIG. 12).

E. Inspect the flue baffle. It should be reasonably clean and

free of soot. Heavy soot formation indicates improper
functioning of the burner. The flue and burner both require
cleaning in the following manner:
1) Unplug the refrigerator power cord from the 120 volt

AC outlet (see FIG. 6).

2) Disconnect or shut off the 12 volt power to the

refrigerator.

3) Turn manual shutoff valve to OFF. (See FIG. 6 & 12).
4) Remove cover from the burner housing. (See FIG . 6).
5) Disconnect the wire from the high voltage electrode.
6) Remove the burner mounting screws and remove the

burner assembly.

7) Remove the flue cap from top of flue tube and lift out

the wire and spiral baffle. Clean the flue from the top
using a flue brush. Blowing compressed air into the
flue will not properly clean soot and scale out of the
flue tube. Replace spiral baffle and flue cap.

8) Clean burner tube with a brush. Blow out burner with

compressed air.

9) Before removing burner jet, clean burner area of soot

and scale that fell out of flue tube. Remove the burner
jet. Soak the jet in wood alcohol and blow it out with
compressed air. Reinstall and tighten burner jet.

DO NOT use a wire or pin when cleaning the burner jet
as damage can occur to the precision opening. This can
cause damage to the refrigerator or create a fire hazard.

10) Reinstall burner, being careful that the end of the

burner fits into the slot on the burner bracket. Check
to make sure slots are centered under the flue tube
and the thermocouple is positioned properly (tip of
thermocouple extends over two slots of burner).

11) Be sure to reconnect the wire to high voltage elec-

trode. Check the electrode for proper location and
gap. (See FIG. 13).

ELECTRODE

BURNER T UBE

Dometic Rv Thermostat Troubleshooting

1/8' T O 3/16'
(3-5 mm)

12) Turn on manual gas shutoff valve and check all

fittings for leaks.

13) Connect 120 volt power cord to the outlet and

reconnect or turn on the 12 volt DC power.

14) Check LP gas safety shutoff. See

Section A. Instal-

lation, Item 9. Testing LP Gas Safety Shutoff.

FIG. 13

F. FUSES
The 2-way models are equipped with 2 fuses, one for the
refrigerator control system and one for the AC cartridge
heater (see Table below). To replace fuse(s) proceed as
follows:

1. Disconnect the wall plug, and the 12 volt wires.
2. Remove the power module cover. See FIG. 6.
3. Snap the fuse out of the fuse holder.
4. Fit a new fuse in to the fuse holder.
5. Replace the power module cover.

Control System 3-amp
AC Heater 5-amp

3. TROUBLESHOOTING

Refrigerator Does Not Cool Properly

A. Burner jet clogged.

Clean. See

Section D. Maintenance & Service, Item 1.

Periodic Maintenance, Paragraph E. Item 1–14.

Dometic Rv Air Conditioner Troubleshooting

B. Check level of refrigerator.
C. Venting problem.

Restriction in air flow across cooling unit.

D. Heavy frost buildup on evaporator fins.

Defrost.

E. Flue baffle not inserted properly in flue tube.
F. Improperly set thermostat.

See

Dometic Rv Ac Installation Manuals

Section C. Operating Instructions, Item 3.

Paragraph F.

Manuals

G. Burner dirty.

Clean. See Section D. Maintenance & Service, Item 1.
Periodic Maintenance, Paragraph E.8.

H. LP gas pressure low at burner.

Set main regulator so pressure does not drop below 11
inches water column at pressure tap.

I. Burner not located properly under flue tube.

Relocate.

J. Burner damaged.

Replace.

K. Odors and fumes.

1. Dislocated burner.
2. Damaged burner
3. Dirty flue tube.